Setting the tresholds for selected components of air in filling the cylinders of autonomous breathing apparatus
Absztrakt :
This paper deals with the determination of the number of engine hours needed to
reach the limits set by the standard STN EN 12021 for clean air in the autonomous
breathing apparatus used by the Fire and Rescue Corps in the Slovak Republic. The
purity of air sucked in affects the life of the filter cartridge P-21 TRIPLEX and its effective
use in the filling of the cylinders of the autonomous breathing apparatus using
compressor Bauer Mariner II. The determination of thresholds of CO, CO 2 , H 2 O and oil at
the outlet of the compressor was performed by the air tester Auer Airtester HP, which is
used to measure the quality and purity of the air supplied to the compressor cylinders.
Jelen írás ismerteti annak meghatározását, hogy mennyi működési órával lehet elérni
az STN EN 12021 készülék szabvány szerinti működési idejének felső határát, mellyel
a Szlovák Köztársaság tűzoltási és mentési szervezetének légzőkészülékeit töltik tiszta
levegővel. A Bauer Mariner II kompresszorral használt P-21 TRIPLEX szűrőbetét a levegő szennyeződéseit nyeli el légzőpalackok töltésekor. Annak meghatározására, hogy
a kompresszor kimeneti oldalán mennyi a CO-, CO 2 -, H 2 O- és olajtartalom, az Auer
Airtester HP készüléket használtuk, így vizsgálva a betöltésre kerülő levegő minőségét
és tisztaságát.